Type II focuses on high- and very-high-pressure appliances other than small appliances
and MVACs. This 25-question mode trains the sequence decisions that matter: identify the
system, recover liquid efficiently, reach the correct evacuation level, and service it safely.
Type II questions frequently combine more than one fact. The required evacuation level can
depend on appliance pressure category, the system's full charge, and whether the recovery
equipment was manufactured before or on/after November 15, 1993. Recovery and charging
questions also test where liquid and vapor are found within the refrigeration circuit.
Leak detection
Oil traces, excessive superheat, testing before charging, and choosing nitrogen safely.
Recovery sequence
Recover liquid first, then vapor; use temperature differences and short, large-diameter hoses to improve speed.
Evacuation decisions
Pressure category, full charge below or at least 200 pounds, equipment date, leak condition, and repair type.
Charging and safety
Liquid versus vapor charging, avoiding compressor slugging, noncondensables, and never energizing a hermetic compressor in a vacuum.
A Better Type II Decision Order
Step
Question to ask
Why it matters
1. Classify
Is this high-, very-high-, medium-, or low-pressure equipment?
Pressure category selects the correct rule row.
2. Size the charge
Is the full charge below 200 pounds or 200 pounds and above?
Several high- and medium-pressure evacuation targets split at 200 pounds.
3. Check equipment date
Was the recovery machine made before or on/after November 15, 1993?
Modern equipment can have a deeper required vacuum.
4. Check the service condition
Is the repair major, non-major, or limited by a leak?
Specific exceptions may change what must be achieved before opening.
The app randomly selects 25 Type II questions and shuffles each answer set.
Explanations emphasize why a condition changes the correct procedure.
Missed questions feed Review Missed and the progress dashboard.
Everything is stored locally in your browser with no account required.
Original Type II Sample Questions
Recovery sequence
Why is liquid refrigerant normally recovered before the remaining vapor from a high-pressure appliance?
Liquid can be removed much faster while most of the charge is still in liquid form
Vapor cannot legally enter a recovery cylinder
Liquid recovery eliminates the need to recover vapor
It adds noncondensables to the system
Answer and explanation
A is correct. Moving the bulk liquid first speeds recovery. Vapor must still be recovered afterward to reach the required level.
Evacuation table
A high-pressure appliance has a full charge below 200 pounds. What evacuation level does EPA's table list with either pre-1993 or post-1993 recovery equipment?
0 inches Hg vacuum
4 inches Hg vacuum
10 inches Hg vacuum
15 inches Hg vacuum
Answer and explanation
A is correct. The high-pressure, under-200-pound row is 0 inches Hg vacuum for both equipment-date columns. Do not borrow the medium-pressure value.
Pressure testing
Which gas is the best general choice for pressurizing a system during leak testing?
Oxygen
Compressed air
Regulated dry nitrogen
Pure refrigerant released afterward
Answer and explanation
C is correct. Nitrogen should be used with a regulator and relief valve. Oxygen or compressed air can react dangerously with refrigerant oil under pressure.
Pressure rise after recovery
After the target vacuum is reached, system pressure rises during a short wait. What is the likely lesson?
Recovery is automatically complete
Refrigerant may still be boiling from trapped liquid or oil
The gauge must always be discarded
Air should be added to stabilize the pressure
Answer and explanation
B is correct. A pressure rebound can show that refrigerant remains in the system or oil and is continuing to vaporize. Recovery should continue as appropriate.
Common Type II Mistakes
Skipping appliance classification
The same charge size can produce a different target in a different pressure category.
Stopping after liquid recovery
Liquid-first is a speed technique, not permission to leave vapor behind.
Ignoring the 200-pound split
Read whether the question says less than 200 or 200 pounds and above.
Energizing a hermetic compressor in vacuum
A compressor motor can be damaged because it is not being cooled normally and electrical arcing risk increases.
Train the whole decision sequence
Take 25 Type II questions, then use Review Missed to isolate evacuation, recovery, leak, or charging weaknesses.