Small appliances and recovery decisions

Free EPA 608 Type I Practice Test

Type I covers factory-sealed small appliances with five pounds or less of refrigerant. This mode builds a 25-question session from the site's original Type I bank and explains why compressor condition, recovery-equipment date, and access location change the answer.

What Type I Actually Covers

EPA defines a small appliance by how it was made and charged, not simply by how small it looks. It must be fully manufactured, charged, and hermetically sealed in a factory with five pounds or less of refrigerant. Examples include household refrigerators and freezers, room air conditioners, dehumidifiers, vending machines, and drinking-water coolers.

Recovery targets

The 80 percent, 90 percent, and four-inches-of-mercury options.

Compressor condition

Why a working compressor can assist system-dependent recovery and an inoperative compressor changes access needs.

Recovery equipment

System-dependent versus self-contained equipment and the November 15, 1993 dividing date.

Service and disposal

Temporary access fittings, refrigerant identification, noncondensables, and the safe-disposal chain.

The 80/90 Rule Without Guessing

ConditionRequired recoveryMemory cue
Recovery equipment made before November 15, 199380 percentOlder recovery equipment means 80 percent.
Post-1993 equipment + working compressor90 percentNewer equipment and a working compressor earn the higher target.
Post-1993 equipment + inoperative compressor80 percentA failed compressor brings the target back to 80 percent.
Alternative for a small applianceEvacuate to 4 inches Hg vacuumThis is an alternative compliance path, not an extra step after the percentage target.

See the full sourced comparison in the recovery and evacuation levels reference.

How This Type I Practice Mode Works

Original Type I Sample Questions

Small-appliance definition

Which detail is required for equipment to fit EPA's small-appliance definition?

  1. It operates below atmospheric pressure
  2. It is factory manufactured, charged, and hermetically sealed with five pounds or less of refrigerant
  3. It is installed in a residence
  4. It can be moved by one technician
Answer and explanation

B is correct. The definition depends on factory manufacture, factory charging, hermetic sealing, and a charge of five pounds or less. Size, portability, and residential use alone do not decide it.

Recovery percentage

A small appliance has a working compressor and is recovered with equipment manufactured after November 15, 1993. What percentage must be recovered?

  1. 70 percent
  2. 80 percent
  3. 90 percent
  4. 100 percent
Answer and explanation

C is correct. Post-1993 recovery equipment plus a functioning compressor requires 90 percent recovery. If the compressor were not functioning, the percentage would be 80 percent.

Inoperative compressor

Why are both high- and low-side access points useful when using system-dependent recovery on a small appliance with an inoperative compressor?

  1. They let trapped refrigerant be removed from both sides of the system
  2. They permanently convert the appliance to a split system
  3. They allow oxygen to push refrigerant into the cylinder
  4. They eliminate the need for a recovery container
Answer and explanation

A is correct. A failed compressor cannot help move refrigerant through the system, so access to both sides helps prevent refrigerant from remaining trapped.

Temporary access fittings

What should normally happen to a solderless access fitting after service is complete?

  1. Leave it permanently as the primary service port
  2. Remove it because it can become a leak point
  3. Fill it with oil
  4. Vent the remaining refrigerant through it
Answer and explanation

B is correct. EPA's Type I topic outline calls out removing solderless access fittings after service; leaving a temporary piercing fitting can create a future leak point.

Common Type I Mistakes

Calling every compact unit a small appliance

Use the complete factory-sealed, factory-charged, five-pound definition.

Remembering 80 and 90 without the conditions

Check equipment date first, then compressor condition.

Expecting a failed compressor to move refrigerant

Without compressor circulation, plan access to both sides and use appropriate recovery techniques.

Treating a piercing valve as permanent

A temporary solderless fitting should not become a long-term leak risk.

Practice the condition, not just the number

Work through 25 Type I questions, then repeat missed compressor and recovery decisions until the rule is automatic.

Launch Type I practice